Precision Column Heating for Consistent LC-MS Performance
Versa Heat R

Versa Heat S

Thermostatizing the column improves peak shapes, minimizes backpressure fluctuations and enhances reproducibility especially in temperature-sensitive proteomics and metabolimics workflows. By eliminating the impact of ambient temperature changes, column heating accelerates sample loading, wash cycles, and improves overall LC-MS system utilization.
Why Column Heating Matters
Stable temperature. Better separations. More reproducible science
In nanoLC-MS workflows, even small changes in temperature can lead to big variations in retention times, peak shapes and reproducibility. Integrating a column heater ensures precision, performance and efficiency across every run.
Key Benefits:
- Consistent Retentions Times – Minimizes RT drift due to ambient temperature variation
- Sharper Peaks & Better Resolution – Ensures optimal mobile phase viscosity
- Faster Loading & Wash Cycles – Enables higher flow rates at constant pressure
- Enables Longer Columns & Smaller Particles – Supports high-efficiency separations
- Improves Uptime – Reduces equilibration time and column wash duration
- Stabilizes Lab Variability – Mitigates room temperature shifts and AC effects
Column temperature control is crucial for ensuring consistent
retention times, peak shapes, and reproducibility in nanoLC
applications.
- Precise Temperature Control: ±1°C accuracy with 0.1°C tolerance for reproducibility.
- Plug & Play Integration: Compatible with Thermo Scientific μPAC Neo HPLC Columns & EASY-Spray Sources.
- Compact & Robust: Lightweight, space-saving, and easy to integrate.
- Enhanced Peak Performance: Reduces retention variability and sharpens peaks.
- Versatile Application: Supports low-flow, capillary, and micro-flow LC-MS workflows.
QuickFit VersaHeat S rapidly reaches and mantains target temperatures, enabling
Higher flow rates, reduced wash times, and exceptional chromatography reproducibility-
independent of room conditions

- Reaches 65 C in under 10 min
- Maintains 0.5 C accuracy
- Higher flow rates with lower back
pressure - Faster column washout cycles
- Plug & Play via Easy-Spray TM jack
control - PACTM optimized design
Montara BioLabs’ QuickFit Column Heaters ensure precise and reliable heating for capillary columns and Thermo Scientific μPAC Neo HPLC Columns, optimizing LC-MS workflows.
Designed for EASY-Spray Ion Sources, they provide efficient heating through a resistor-based PCB contact, powered via the EASY-Spray jack connection, enhancing performance and reproducibility.
Seamless Integration for Your LC-MS Workflows

- Precise Temperature Control: ±1°C accuracy with 0.1°C tolerance for reproducibility.
- Plug & Play Integration: Compatible with a large number of column arrangements
- Compact & Robust: Lightweight, spacesaving, and easy to integrate.
- Enhanced Peak Performance: Reduces retention variability and sharpens peaks.
- Versatile Application: Supports low-flow, capillary, and micro-flow LC-MS workflows.
Accelerated Ramp-Up. Stable Output. Reliable Performance

- Reaches target temperature in under 1 min
- Maintains 0.5 ºC accuracy
- Higher flow rates with lower back pressure, avoid system shoutdown
- Optimized design for Plug & Play
- Plug & Play with EVOSEP™ One and Thermo EasySpray™
- Validated on EVOSEP™ One with 25% lower back pressure
Seamless Integration for Your LC-MS Workflows


Ion Sources

QF Columns

Emitters

QF Emitters